This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.

Intra-Cardiac versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion with a Watchman FLX Device / Pastormerlo, L. E.; Tondo, C.; Fassini, G.; Nicosia, A.; Ronco, F.; Contarini, M.; Giacchi, G.; Grasso, C.; Casu, G.; Romeo, M. R.; Mazzone, P.; Limite, L.; Caramanno, G.; Geraci, S.; Pagnotta, P.; Chiarito, M.; Tamburino, C.; Berti, S.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:20(2023). [10.3390/jcm12206658]

Intra-Cardiac versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion with a Watchman FLX Device

Contarini M.;Casu G.;Mazzone P.;Berti S.
2023-01-01

Abstract

This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.
2023
Intra-Cardiac versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion with a Watchman FLX Device / Pastormerlo, L. E.; Tondo, C.; Fassini, G.; Nicosia, A.; Ronco, F.; Contarini, M.; Giacchi, G.; Grasso, C.; Casu, G.; Romeo, M. R.; Mazzone, P.; Limite, L.; Caramanno, G.; Geraci, S.; Pagnotta, P.; Chiarito, M.; Tamburino, C.; Berti, S.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:20(2023). [10.3390/jcm12206658]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/323770
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact