Analyte quantification in first generation electrochemical biosensors is threatened by electro-active molecules, such as ascorbic acid (AA). Electrochemical deposition ofortho-phenylendiamine (oPD) on transducer considerably reduces AA interfering. These properties of poly-oPD (PPD) are influenced by electro-polymerization conditions. Chronoamperometry (CA) is proposed as an alternative technique foroPD electro-deposition over Pt. Pt/PPD sensors are evaluated through functional parameters related to AA rejection and analytical performances. N-2, O-2, and air bubbled supporting electrolyte and several step duration times are used. Best performing CA-PPD sensor is obtained in N-2-purged phosphate solution containing 300 mMoPD by means of a 1 s step duration/120 steps CA. High performing PPD is achieved in shorter time compared to commonly used constant potential amperometry. Aging of polymeric features and scanning electron microscopy investigations are performed and optimized CA electro-polymerization conditions are used to build up an efficient interference blocking layer in a glucose oxidase biosensor.

Chronoamperometry as effective alternative technique for electro-synthesis of ortho-phenylendiamine permselective films for biosensor applications / Monti, P.; Bacciu, A.; Arrigo, P.; Marceddu, S.; Migheli, Q.; Serra, P. A.; Rocchitta, G.. - In: JOURNAL OF APPLIED POLYMER SCIENCE. - ISSN 0021-8995. - 137:39(2020), p. 49172. [10.1002/app.49172]

Chronoamperometry as effective alternative technique for electro-synthesis of ortho-phenylendiamine permselective films for biosensor applications

Monti P.
;
Bacciu A.;Arrigo P.;Migheli Q.;Serra P. A.;Rocchitta G.
2020-01-01

Abstract

Analyte quantification in first generation electrochemical biosensors is threatened by electro-active molecules, such as ascorbic acid (AA). Electrochemical deposition ofortho-phenylendiamine (oPD) on transducer considerably reduces AA interfering. These properties of poly-oPD (PPD) are influenced by electro-polymerization conditions. Chronoamperometry (CA) is proposed as an alternative technique foroPD electro-deposition over Pt. Pt/PPD sensors are evaluated through functional parameters related to AA rejection and analytical performances. N-2, O-2, and air bubbled supporting electrolyte and several step duration times are used. Best performing CA-PPD sensor is obtained in N-2-purged phosphate solution containing 300 mMoPD by means of a 1 s step duration/120 steps CA. High performing PPD is achieved in shorter time compared to commonly used constant potential amperometry. Aging of polymeric features and scanning electron microscopy investigations are performed and optimized CA electro-polymerization conditions are used to build up an efficient interference blocking layer in a glucose oxidase biosensor.
2020
Chronoamperometry as effective alternative technique for electro-synthesis of ortho-phenylendiamine permselective films for biosensor applications / Monti, P.; Bacciu, A.; Arrigo, P.; Marceddu, S.; Migheli, Q.; Serra, P. A.; Rocchitta, G.. - In: JOURNAL OF APPLIED POLYMER SCIENCE. - ISSN 0021-8995. - 137:39(2020), p. 49172. [10.1002/app.49172]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/302566
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact