A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic–lipophilic balance cartridges which gave good recoveries and lowmatrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water–acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data.

Validated LC–MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylaminesc in Amniotic Fluid / Burrai, L; Nieddu, M; Carta, Antonio; Trignano, C; Sanna, R; Boatto, Gianpiero. - In: JOURNAL OF ANALYTICAL TOXICOLOGY. - ISSN 0146-4760. - 40:3(2016), pp. 194-200. [10.1093/jat/bkv143]

Validated LC–MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylaminesc in Amniotic Fluid

CARTA, Antonio;Trignano C;BOATTO, Gianpiero
2016-01-01

Abstract

A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic–lipophilic balance cartridges which gave good recoveries and lowmatrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water–acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data.
2016
Validated LC–MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylaminesc in Amniotic Fluid / Burrai, L; Nieddu, M; Carta, Antonio; Trignano, C; Sanna, R; Boatto, Gianpiero. - In: JOURNAL OF ANALYTICAL TOXICOLOGY. - ISSN 0146-4760. - 40:3(2016), pp. 194-200. [10.1093/jat/bkv143]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/59351
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact