A computer-aided detection (CAD) system for the selection of lung nodules in computer tomography (CT) images is presented. The system is based on region growing (RG) algorithms and a new active contour model (ACM), implementing a local convex hull, able to draw the correct contour of the lung parenchyma and to include the pleural nodules. The CAD consists of three steps: (1) the lung parenchymal volume is segmented by means of a RG algorithm; the pleural nodules are included through the new ACM technique; (2) a RG algorithm is iteratively applied to the previously segmented volume in order to detect the candidate nodules; (3) a double-threshold cut and a neural network are applied to reduce the false positives (FPs). After having set the parameters on a clinical CT, the system works on whole scans, without the need for any manual selection. The CT database was recorded at the Pisa center of the ITALUNG-CT trial, the first Italian randomized controlled trial for the screening of the lung cancer. The detection rate of the system is 88.5% with 6.6 FPs/CT on 15 CT scans (about 4700 sectional images) with 26 nodules: 15 internal and 11 pleural. A reduction to 2.47 FPs/CT is achieved at 80% efficiency.

A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model / Bellotti, R.; DE CARLO, F.; Gargano, G.; Tangaro, S.; Cascio, D.; Catanzariti, E.; Cerello, P.; Cheran, S. C.; Delogu, P.; DE MITRI, I.; Fulcheri, C.; Grosso, D.; Retico, A.; Squarcia, S.; Tommasi, E.; Golosio, Bruno. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 34:12(2007), pp. 4901-4910. [10.1118/1.2804720]

A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model

GOLOSIO, Bruno
2007-01-01

Abstract

A computer-aided detection (CAD) system for the selection of lung nodules in computer tomography (CT) images is presented. The system is based on region growing (RG) algorithms and a new active contour model (ACM), implementing a local convex hull, able to draw the correct contour of the lung parenchyma and to include the pleural nodules. The CAD consists of three steps: (1) the lung parenchymal volume is segmented by means of a RG algorithm; the pleural nodules are included through the new ACM technique; (2) a RG algorithm is iteratively applied to the previously segmented volume in order to detect the candidate nodules; (3) a double-threshold cut and a neural network are applied to reduce the false positives (FPs). After having set the parameters on a clinical CT, the system works on whole scans, without the need for any manual selection. The CT database was recorded at the Pisa center of the ITALUNG-CT trial, the first Italian randomized controlled trial for the screening of the lung cancer. The detection rate of the system is 88.5% with 6.6 FPs/CT on 15 CT scans (about 4700 sectional images) with 26 nodules: 15 internal and 11 pleural. A reduction to 2.47 FPs/CT is achieved at 80% efficiency.
2007
A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model / Bellotti, R.; DE CARLO, F.; Gargano, G.; Tangaro, S.; Cascio, D.; Catanzariti, E.; Cerello, P.; Cheran, S. C.; Delogu, P.; DE MITRI, I.; Fulcheri, C.; Grosso, D.; Retico, A.; Squarcia, S.; Tommasi, E.; Golosio, Bruno. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 34:12(2007), pp. 4901-4910. [10.1118/1.2804720]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/57899
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 102
  • ???jsp.display-item.citation.isi??? 84
social impact