The fluorescence spectra from rat bones of different age groups (8, 56 and 78 weeks) and lumber vertebra were measured with 8, 10 and 12 keV synchrotron X-rays. We have utilized the new hard X-ray micro-spectroscopy beamline facility, X27A, available at NSLS with a primary beam spot size of the order of similar to 10 mu m. With this spatial resolution and high flux throughput, X-ray fluorescent intensities for Ca and other trace elements were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. Regarding the lumber vertebra, we acquired the fluorescence spectra from the left, right and middle portions and calcium accumulation was evaluated and compared with the other samples. We have identified the major trace elements of Ca, Ni, Fe and Zn and minor trace elements of Ti, Cr and Mn in the sample. The percentage of scattered radiation and trace element contributions from these samples were highlighted at different energies. (C) 2008 Elsevier B.V. All rights reserved.

Synchrotron-induced X-ray fluorescence from rat bone and lumber vertebra of different age groups RID F-3370-2011 / Rao, Dv; Swapna, M; Cesareo, R; Brunetti, Antonio; Akatsuka, T; Yuasa, T; Takeda, T; Tromba, G; Gigante, Ge. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - 267:3(2009), pp. 502-505. [10.1016/j.nimb.2008.11.013]

Synchrotron-induced X-ray fluorescence from rat bone and lumber vertebra of different age groups RID F-3370-2011

BRUNETTI, Antonio;
2009-01-01

Abstract

The fluorescence spectra from rat bones of different age groups (8, 56 and 78 weeks) and lumber vertebra were measured with 8, 10 and 12 keV synchrotron X-rays. We have utilized the new hard X-ray micro-spectroscopy beamline facility, X27A, available at NSLS with a primary beam spot size of the order of similar to 10 mu m. With this spatial resolution and high flux throughput, X-ray fluorescent intensities for Ca and other trace elements were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. Regarding the lumber vertebra, we acquired the fluorescence spectra from the left, right and middle portions and calcium accumulation was evaluated and compared with the other samples. We have identified the major trace elements of Ca, Ni, Fe and Zn and minor trace elements of Ti, Cr and Mn in the sample. The percentage of scattered radiation and trace element contributions from these samples were highlighted at different energies. (C) 2008 Elsevier B.V. All rights reserved.
2009
Synchrotron-induced X-ray fluorescence from rat bone and lumber vertebra of different age groups RID F-3370-2011 / Rao, Dv; Swapna, M; Cesareo, R; Brunetti, Antonio; Akatsuka, T; Yuasa, T; Takeda, T; Tromba, G; Gigante, Ge. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - 267:3(2009), pp. 502-505. [10.1016/j.nimb.2008.11.013]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/49351
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact