We have developed a Real-Time PCR assay to detect M. tuberculosis using the iCycler iQ detection system by TaqMan assay directly on the clinical specimen. A total of 513 clinical samples were taken from patients with suspected tuberculosis and other patients that had an active mycobacterial infection, as well as patients with diagnosed tuberculosis who were receiving antitubercular therapy. The sensitivity and specificity of this assay, 10% and 100%, respectively, were compared to those of conventional microbiological methods.

We have developed a Real-Time PCR assay to detect M. tuberculosis using the iCycler iQ detection system by TaqMan assay directly on the clinical specimen. A total of 513 clinical samples were taken from patients with suspected tuberculosis and other patients that had an active mycobacterial infection, as well as patients with diagnosed tuberculosis who were receiving antitubercular therapy. The sensitivity and specificity of this assay, 10% and 100%, respectively, were compared to those of conventional microbiological methods.

Rapid detection and identification of Mycobacterium tuberculosis by Real Time PCR and Bactec 960 MIGT / Ortu, Silvia; Molicotti, Paola; Sechi, Leonardo Antonio; Pirina, Pietro; Saba, F; Vertuccio, C; Deriu, A; Maida, Ivana; Mura, Maria Stella Anna; Zanetti, S.. - In: NEW MICROBIOLOGICA. - ISSN 1121-7138. - 29:(2006), pp. 75-80.

Rapid detection and identification of Mycobacterium tuberculosis by Real Time PCR and Bactec 960 MIGT

ORTU, Silvia;MOLICOTTI, Paola;SECHI, Leonardo Antonio;PIRINA, Pietro;MAIDA, Ivana;MURA, Maria Stella Anna;
2006-01-01

Abstract

We have developed a Real-Time PCR assay to detect M. tuberculosis using the iCycler iQ detection system by TaqMan assay directly on the clinical specimen. A total of 513 clinical samples were taken from patients with suspected tuberculosis and other patients that had an active mycobacterial infection, as well as patients with diagnosed tuberculosis who were receiving antitubercular therapy. The sensitivity and specificity of this assay, 10% and 100%, respectively, were compared to those of conventional microbiological methods.
2006
Inglese
29
75
80
6
Sì, ma tipo non specificato
We have developed a Real-Time PCR assay to detect M. tuberculosis using the iCycler iQ detection system by TaqMan assay directly on the clinical specimen. A total of 513 clinical samples were taken from patients with suspected tuberculosis and other patients that had an active mycobacterial infection, as well as patients with diagnosed tuberculosis who were receiving antitubercular therapy. The sensitivity and specificity of this assay, 10% and 100%, respectively, were compared to those of conventional microbiological methods.
Ortu, Silvia; Molicotti, Paola; Sechi, Leonardo Antonio; Pirina, Pietro; Saba, F; Vertuccio, C; Deriu, A; Maida, Ivana; Mura, Maria Stella Anna; Zanet...espandi
Rapid detection and identification of Mycobacterium tuberculosis by Real Time PCR and Bactec 960 MIGT / Ortu, Silvia; Molicotti, Paola; Sechi, Leonardo Antonio; Pirina, Pietro; Saba, F; Vertuccio, C; Deriu, A; Maida, Ivana; Mura, Maria Stella Anna; Zanetti, S.. - In: NEW MICROBIOLOGICA. - ISSN 1121-7138. - 29:(2006), pp. 75-80.
info:eu-repo/semantics/article
1 Contributo su Rivista::1.1 Articolo in rivista
262
10
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/44536
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 12
social impact