: Robotic abdominal wall surgery (RAWS) has expanded rapidly, enabling minimally invasive access to retromuscular and preperitoneal planes previously dominated by open techniques. Real-world data on its uptake and barriers remain limited. A 66-item cross-sectional, anonymous, web-based questionnaire was openly distributed in 2025-2026 through hernia interest groups and personal networks. Reporting follows the CHERRIES checklist. Analyses were descriptive and exploratory; categorical variables are reported as n (%); no inferential testing was performed. No patient-level outcomes were collected. Overall, 161 surgeons from 22 countries responded, the majority from Italy (102/161; 63.4%); 15 of the other 21 countries contributed ≤3 respondents each. The Da Vinci Xi dominated (128/161; 79.5%); 65.8% owned a single system and only 8.7% had daily console access. RAWS was performed in 109/161 units (67.7%); robotic TAPP for inguinal hernia was most frequent (33.5%), whereas roboTAR was rated the greatest robotic advantage (16.8%). Robotics reportedly shifted the preferred mesh plane toward retromuscular/preperitoneal placement in 31.7%, and 29.2% performed techniques not offered by open or laparoscopic surgery. It was perceived as more expensive than laparoscopy across all subtypes, and only 11.2% identified a specific reimbursement code. Cost (77.6%) and operating-room time (55.3%) were the leading barriers; 77.6% expected RAWS to grow and 87.0% would join international registries. Descriptively, Italian respondents tended to report lower console access and per-surgeon volume than non-Italian respondents. In this predominantly Italian convenience sample, RAWS adoption was reportedly expanding but structurally constrained. Findings reflect self-reported practice and perceptions, are not internationally representative, and warrant prospective registry-based evidence.

Adoption, technique, and barriers in robotic abdominal wall surgery: the GLOBAL-HERNIA cross-sectional survey / Brucchi, F., Formisano, G., Esposito, S., Piccoli, M., Bianchi, P.P., Dionigi, G., Muysoms, F., Null, N., Amato, L., Andreuccetti, J., Antonelli, A., Argenio, G., Bacchiocchi, G., Baldari, L., Barranquero, A.G., Basile, E., Bellio, G., Zobel, L.B., Berrevoet, F., Blanc, P., et al.. - In: JOURNAL OF ROBOTIC SURGERY. - ISSN 1863-2491. - 20:1(2026). [10.1007/s11701-026-04026-9]

Adoption, technique, and barriers in robotic abdominal wall surgery: the GLOBAL-HERNIA cross-sectional survey

Perra, Teresa
Membro del Collaboration Group
;
Porcu, Alberto
Membro del Collaboration Group
;
2026-01-01

Abstract

: Robotic abdominal wall surgery (RAWS) has expanded rapidly, enabling minimally invasive access to retromuscular and preperitoneal planes previously dominated by open techniques. Real-world data on its uptake and barriers remain limited. A 66-item cross-sectional, anonymous, web-based questionnaire was openly distributed in 2025-2026 through hernia interest groups and personal networks. Reporting follows the CHERRIES checklist. Analyses were descriptive and exploratory; categorical variables are reported as n (%); no inferential testing was performed. No patient-level outcomes were collected. Overall, 161 surgeons from 22 countries responded, the majority from Italy (102/161; 63.4%); 15 of the other 21 countries contributed ≤3 respondents each. The Da Vinci Xi dominated (128/161; 79.5%); 65.8% owned a single system and only 8.7% had daily console access. RAWS was performed in 109/161 units (67.7%); robotic TAPP for inguinal hernia was most frequent (33.5%), whereas roboTAR was rated the greatest robotic advantage (16.8%). Robotics reportedly shifted the preferred mesh plane toward retromuscular/preperitoneal placement in 31.7%, and 29.2% performed techniques not offered by open or laparoscopic surgery. It was perceived as more expensive than laparoscopy across all subtypes, and only 11.2% identified a specific reimbursement code. Cost (77.6%) and operating-room time (55.3%) were the leading barriers; 77.6% expected RAWS to grow and 87.0% would join international registries. Descriptively, Italian respondents tended to report lower console access and per-surgeon volume than non-Italian respondents. In this predominantly Italian convenience sample, RAWS adoption was reportedly expanding but structurally constrained. Findings reflect self-reported practice and perceptions, are not internationally representative, and warrant prospective registry-based evidence.
2026
Adoption, technique, and barriers in robotic abdominal wall surgery: the GLOBAL-HERNIA cross-sectional survey / Brucchi, F., Formisano, G., Esposito, S., Piccoli, M., Bianchi, P.P., Dionigi, G., Muysoms, F., Null, N., Amato, L., Andreuccetti, J., Antonelli, A., Argenio, G., Bacchiocchi, G., Baldari, L., Barranquero, A.G., Basile, E., Bellio, G., Zobel, L.B., Berrevoet, F., Blanc, P., et al.. - In: JOURNAL OF ROBOTIC SURGERY. - ISSN 1863-2491. - 20:1(2026). [10.1007/s11701-026-04026-9]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/394409
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact