ObjectivesTo evaluate the 1-year effectiveness and safety of the XEN45, either alone or in combination with phacoemulsification, in glaucoma patients.MethodsThis multicentre, prospective, observational study included consecutive eyes of glaucoma patients from the Italian XEN-Glaucoma Treatment Registry (XEN-GTR) who underwent XEN45 alone or in combination with phacoemulsification, with at least 1 year of follow-up. Surgical success was defined as intraocular pressure (IOP) < 18 mmHg and & GE;20% reduction from preoperative IOP, over 1 year of follow-up.ResultsTwo hundred thirty-nine eyes (239 patients) were analyzed, 144 (60.2%) eyes in the XEN-solo and 95 (39.8%) eyes in the XEN+Phaco groups. One hundred-sixty-eight (70.3%) eyes achieved overall success, without statistically significant differences between study groups (p = 0.07). Preoperative IOP dropped from a median (IQR) of 23.0 (20.0-26.0) mmHg to 14.0 (12.0-16.0) mmHg at month 12 (p < 0.001), with overall 39.9 & PLUSMN; 18.3% IOP reduction. The mean number of preoperative ocular hypotensive medications (OHM) was significantly reduced from 2.7 & PLUSMN; 0.9 to 0.5 & PLUSMN; 0.9 at month 12 (p < 0.001). Preoperative IOP < 15 mmHg (HR: 6.63; 95%CI: 2.61-16.84, p < 0.001) and temporal position of the surgeon (HR: 4.25; 95%CI: 2.62-6.88, p < 0.001) were significantly associated with surgery failure. One hundred-forty-six (61.1%) eyes had no intraoperative complications, whereas 91 (38.1%) and 56 (23.4%) eyes experienced at least one complication, respectively early (< month 1) and late (& GE; month 1), all self-limiting or successfully treated without sequelae. Needling occurred in 55 (23.0%) eyes at least once during follow-up.ConclusionOver 1-year follow-up, XEN45 alone or in combination with phacoemulsification, had comparable success rates and effectively and safely lowered IOP and the need for OHM.

Effectiveness and safety of XEN45 implant over 12 months of follow-up: data from the XEN-Glaucoma Treatment Registry / Oddone, Francesco; Roberti, Gloria; Giammaria, Sara; Posarelli, Chiara; Ghirelli, Giorgio; Mastropasqua, Leonardo; Agnifili, Luca; Micelli Ferrari, Tommaso; Pace, Vincenzo; Nucci, Paolo; Sacchi, Matteo; Monsellato, Gianluca; Altafini, Romeo; Scuderi, Gianluca; Perdicchi, Andrea; Uva, Maurizio; Carnevale, Carmela; Covello, Giuseppe; Maglionico, Maria Novella; Fea, Antonio; Figus, Michele. - In: EYE. - ISSN 1476-5454. - 38:1(2024). [10.1038/s41433-023-02642-5]

Effectiveness and safety of XEN45 implant over 12 months of follow-up: data from the XEN-Glaucoma Treatment Registry

Sacchi, Matteo;
2024-01-01

Abstract

ObjectivesTo evaluate the 1-year effectiveness and safety of the XEN45, either alone or in combination with phacoemulsification, in glaucoma patients.MethodsThis multicentre, prospective, observational study included consecutive eyes of glaucoma patients from the Italian XEN-Glaucoma Treatment Registry (XEN-GTR) who underwent XEN45 alone or in combination with phacoemulsification, with at least 1 year of follow-up. Surgical success was defined as intraocular pressure (IOP) < 18 mmHg and & GE;20% reduction from preoperative IOP, over 1 year of follow-up.ResultsTwo hundred thirty-nine eyes (239 patients) were analyzed, 144 (60.2%) eyes in the XEN-solo and 95 (39.8%) eyes in the XEN+Phaco groups. One hundred-sixty-eight (70.3%) eyes achieved overall success, without statistically significant differences between study groups (p = 0.07). Preoperative IOP dropped from a median (IQR) of 23.0 (20.0-26.0) mmHg to 14.0 (12.0-16.0) mmHg at month 12 (p < 0.001), with overall 39.9 & PLUSMN; 18.3% IOP reduction. The mean number of preoperative ocular hypotensive medications (OHM) was significantly reduced from 2.7 & PLUSMN; 0.9 to 0.5 & PLUSMN; 0.9 at month 12 (p < 0.001). Preoperative IOP < 15 mmHg (HR: 6.63; 95%CI: 2.61-16.84, p < 0.001) and temporal position of the surgeon (HR: 4.25; 95%CI: 2.62-6.88, p < 0.001) were significantly associated with surgery failure. One hundred-forty-six (61.1%) eyes had no intraoperative complications, whereas 91 (38.1%) and 56 (23.4%) eyes experienced at least one complication, respectively early (< month 1) and late (& GE; month 1), all self-limiting or successfully treated without sequelae. Needling occurred in 55 (23.0%) eyes at least once during follow-up.ConclusionOver 1-year follow-up, XEN45 alone or in combination with phacoemulsification, had comparable success rates and effectively and safely lowered IOP and the need for OHM.
2024
Effectiveness and safety of XEN45 implant over 12 months of follow-up: data from the XEN-Glaucoma Treatment Registry / Oddone, Francesco; Roberti, Gloria; Giammaria, Sara; Posarelli, Chiara; Ghirelli, Giorgio; Mastropasqua, Leonardo; Agnifili, Luca; Micelli Ferrari, Tommaso; Pace, Vincenzo; Nucci, Paolo; Sacchi, Matteo; Monsellato, Gianluca; Altafini, Romeo; Scuderi, Gianluca; Perdicchi, Andrea; Uva, Maurizio; Carnevale, Carmela; Covello, Giuseppe; Maglionico, Maria Novella; Fea, Antonio; Figus, Michele. - In: EYE. - ISSN 1476-5454. - 38:1(2024). [10.1038/s41433-023-02642-5]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/326859
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact