Purpose To describe and compare the conjunctival filtering bleb features after XEN gel implantation and trabeculectomy using anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Methods Fifty-two patients who underwent completely successful trabeculectomy (24 eyes) or completely successful XEN gel implantation (28 eyes) were consecutively enrolled. At the sixth-month follow-up, filtering blebs were analyzed with AS-OCT and IVCM. The main outcomes were the following: (i) bleb-wall epithelium cyst-like structure density and area (BECSD, BSCSA), (ii) bleb-wall sub-epithelium cyst-like structure density and area (BSCSD, BSCSA,), (iii) bleb-wall thickness (BT), (iv) bleb-wall epithelial thickness (BET), (v) bleb-wall reflectivity (BR), and (vi) bleb height (BH), for AS-OCT. Mean microcyst density (MMD) and area (MMA) and stromal meshwork reflectivity (SMR) were the IVCM outcomes. Results Six-month intraocular pressure was 11.46 +/- 3.09 and 10.06 +/- 3.39 mmHg in the XEN gel implantation and trabeculectomy, respectively (p > 0.05). At AS-OCT, XEN gel blebs showed lower BH, BT, BET, BR, (p < 0.001), and BECSA values (p < 0.005), and a higher BECSD (p < 0.05) compared with trabeculectomy blebs. At IVCM, MMA and SMR values were lower in the XEN gel implantation, compared with trabeculectomy (p < 0.05). BECSD and BSCSD negatively correlated with BR (p < 0.01; r = - 0.110; p < 0.01; r = - 0.249), whereas BR strongly correlated with SMR (p < 0.001; r = 0.819). Conclusion Successful filtering blebs after XEN gel implantation appeared flatter and thinner, with a higher number of epithelial cysts and a hypo-reflective bleb wall compared with trabeculectomy. These aspects may depend on the different intra-operative tissue manipulation and/or on different aqueous humor dynamics in the sub-conjunctiva between surgeries.

Structural imaging of conjunctival filtering blebs in XEN gel implantation and trabeculectomy: a confocal and anterior segment optical coherence tomography study / Sacchi, Matteo; Agnifili, Luca; Brescia, Lorenza; Oddone, Francesco; Villani, Edoardo; Nucci, Paolo; Mastropasqua, Leonardo. - In: GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY. - ISSN 1435-702X. - 258:8(2020). [10.1007/s00417-020-04671-2]

Structural imaging of conjunctival filtering blebs in XEN gel implantation and trabeculectomy: a confocal and anterior segment optical coherence tomography study

Sacchi, Matteo;
2020-01-01

Abstract

Purpose To describe and compare the conjunctival filtering bleb features after XEN gel implantation and trabeculectomy using anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Methods Fifty-two patients who underwent completely successful trabeculectomy (24 eyes) or completely successful XEN gel implantation (28 eyes) were consecutively enrolled. At the sixth-month follow-up, filtering blebs were analyzed with AS-OCT and IVCM. The main outcomes were the following: (i) bleb-wall epithelium cyst-like structure density and area (BECSD, BSCSA), (ii) bleb-wall sub-epithelium cyst-like structure density and area (BSCSD, BSCSA,), (iii) bleb-wall thickness (BT), (iv) bleb-wall epithelial thickness (BET), (v) bleb-wall reflectivity (BR), and (vi) bleb height (BH), for AS-OCT. Mean microcyst density (MMD) and area (MMA) and stromal meshwork reflectivity (SMR) were the IVCM outcomes. Results Six-month intraocular pressure was 11.46 +/- 3.09 and 10.06 +/- 3.39 mmHg in the XEN gel implantation and trabeculectomy, respectively (p > 0.05). At AS-OCT, XEN gel blebs showed lower BH, BT, BET, BR, (p < 0.001), and BECSA values (p < 0.005), and a higher BECSD (p < 0.05) compared with trabeculectomy blebs. At IVCM, MMA and SMR values were lower in the XEN gel implantation, compared with trabeculectomy (p < 0.05). BECSD and BSCSD negatively correlated with BR (p < 0.01; r = - 0.110; p < 0.01; r = - 0.249), whereas BR strongly correlated with SMR (p < 0.001; r = 0.819). Conclusion Successful filtering blebs after XEN gel implantation appeared flatter and thinner, with a higher number of epithelial cysts and a hypo-reflective bleb wall compared with trabeculectomy. These aspects may depend on the different intra-operative tissue manipulation and/or on different aqueous humor dynamics in the sub-conjunctiva between surgeries.
2020
Structural imaging of conjunctival filtering blebs in XEN gel implantation and trabeculectomy: a confocal and anterior segment optical coherence tomography study / Sacchi, Matteo; Agnifili, Luca; Brescia, Lorenza; Oddone, Francesco; Villani, Edoardo; Nucci, Paolo; Mastropasqua, Leonardo. - In: GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY. - ISSN 1435-702X. - 258:8(2020). [10.1007/s00417-020-04671-2]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/326689
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
social impact