The Advanced Breast Biopsy Instrumentation (ABBI) system, which uses surgical cannulas up to 20 mm in diameter, is an alternative to conventional surgical biopsy for the diagnosis of non-palpable breast lesions. Since the need for radiological skill outweighs the surgical content of the technique, we evaluated the feasibility of complete management of the procedure by interventional radiologists. 35 of the 111 patients originally scheduled for the procedure were excluded, three because the lesion could not be visualized and 32 because of insufficient thickness of the compressed breast. The procedure had to be abandoned in one case due to a technical failure. 77 stereotactic excisional breast biopsy procedures were performed using the ABBI system in 75 patients with suspicious non-palpable mammographic lesions. The procedure was carried out under local anaesthesia in the radiology department, using a dedicated Lorad (R) radiographic system. 31 (40%) masses without calcifications, 11 (14%) masses with calcifications and 35 (46%) clusters of microcalcifications without tumour mass were sampled. 43 (56%) benign lesions and 34 (44%) malignant lesions were diagnosed. The overall mean diameter of the lesions was 8.7 mm (range 3-22 mm). All 34 patients with malignancies and lobular carcinoma in situ subsequently underwent surgery, the results of which are reported. Three (4%) haematomas were detected and aspirated percutaneously. Two technical problems occurred: an ABBI cannula malfunction, and a computer failure of the digital imaging system during the procedure. The average procedure time was 80 min and the cost of each procedure was 2800000 Italian lire (1555 USS). It is concluded that tissue sampling with the ABBI system can be performed entirely by radiologists without significant problems. The procedure was well tolerated by all patients. The quality of the biopsy specimen was identical to that of a surgical specimen but with the advantages of stereotactic precision for localization of the lesion. © 1998 The British Institute of Radiology.

Stereotactic excisional breast biopsy performed by interventional radiologists using the advanced breast biopsy instrumentation system / Damascelli, B.; Frigerio, L. F.; Lanocita, R.; Patelli, G.; Viganotti, G.; Di Tolla, G.; Magnoni, S.; Ticha, V.; Galante, E.; Attili, A.; Saccozzi, R.; Tomasich, G.. - In: BRITISH JOURNAL OF RADIOLOGY. - ISSN 0007-1285. - 71:850(1998), pp. 1003-1011. [10.1259/bjr.71.850.10211058]

Stereotactic excisional breast biopsy performed by interventional radiologists using the advanced breast biopsy instrumentation system

Magnoni S.;
1998-01-01

Abstract

The Advanced Breast Biopsy Instrumentation (ABBI) system, which uses surgical cannulas up to 20 mm in diameter, is an alternative to conventional surgical biopsy for the diagnosis of non-palpable breast lesions. Since the need for radiological skill outweighs the surgical content of the technique, we evaluated the feasibility of complete management of the procedure by interventional radiologists. 35 of the 111 patients originally scheduled for the procedure were excluded, three because the lesion could not be visualized and 32 because of insufficient thickness of the compressed breast. The procedure had to be abandoned in one case due to a technical failure. 77 stereotactic excisional breast biopsy procedures were performed using the ABBI system in 75 patients with suspicious non-palpable mammographic lesions. The procedure was carried out under local anaesthesia in the radiology department, using a dedicated Lorad (R) radiographic system. 31 (40%) masses without calcifications, 11 (14%) masses with calcifications and 35 (46%) clusters of microcalcifications without tumour mass were sampled. 43 (56%) benign lesions and 34 (44%) malignant lesions were diagnosed. The overall mean diameter of the lesions was 8.7 mm (range 3-22 mm). All 34 patients with malignancies and lobular carcinoma in situ subsequently underwent surgery, the results of which are reported. Three (4%) haematomas were detected and aspirated percutaneously. Two technical problems occurred: an ABBI cannula malfunction, and a computer failure of the digital imaging system during the procedure. The average procedure time was 80 min and the cost of each procedure was 2800000 Italian lire (1555 USS). It is concluded that tissue sampling with the ABBI system can be performed entirely by radiologists without significant problems. The procedure was well tolerated by all patients. The quality of the biopsy specimen was identical to that of a surgical specimen but with the advantages of stereotactic precision for localization of the lesion. © 1998 The British Institute of Radiology.
1998
Stereotactic excisional breast biopsy performed by interventional radiologists using the advanced breast biopsy instrumentation system / Damascelli, B.; Frigerio, L. F.; Lanocita, R.; Patelli, G.; Viganotti, G.; Di Tolla, G.; Magnoni, S.; Ticha, V.; Galante, E.; Attili, A.; Saccozzi, R.; Tomasich, G.. - In: BRITISH JOURNAL OF RADIOLOGY. - ISSN 0007-1285. - 71:850(1998), pp. 1003-1011. [10.1259/bjr.71.850.10211058]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/325729
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? ND
social impact