Background. Defects involving hypopharynx, cervical, and thoracic esophagus are challenging to reconstruct, and the available procedures usually leave patients voiceless. We describe our experience with a modified pedicled ileocolon flap for the reconstruction of alimentary conduit and voice in patients undergoing hypopharyngo-laryngectomy and total esophagectomy.Methods. Between January 1995 and December 2008, 7 patients underwent reconstruction of the digestive tract and voice function with a pedicled ileocolon flap because of extensive defects involving larynx, hyphopharynx, cervical, and thoracic esophagus. Patient's charts were reviewed and appropriate clinical data were evaluated.Results. All patients were male with a mean age of 58 years. The continuity of the digestive tract was restored with ileum-colon (n = 1) or colon (n = 6). The voice tube was reconstructed with appendix (n = 1) or with terminal ileum (n = 6). The middle colic artery (n = 1) and left ascending colic artery (n = 6) were used as a pedicle. Five flaps were supercharged using ileocolic vessels. All the flaps survived completely. No intraoperative or in-hospital mortalities occurred. The mean hospital stay was 40 days. The mean follow-up was 22.4 months. Two patients died of local recurrence (1 patient) and distant metastasis (I patient). One patient died of the complications of pre-existing disease. At the last follow-up, the median deglutition score was 5/7. The median speech score for intelligibility and fluency was 3, and 4 for loudness. The maximum phonation time was 7.57 s. The average sound pressure loudness and fundamental frequency were, respectively, 59 +/- 3 dB and 133 +/- 33 Hz.Conclusion. The pedicled ileocolon flap as used in this series proved to be a safe and reliable technique for simultaneous reconstruction of voice and digestive tract. (Surgery 2011;149:662-71.)

Simultaneous restoration of voice function and digestive tract continuity in patients with synchronous primaries of hypopharynx and thoracic esophagus with pedicled ileocolon flap / Chen, Hung-Chi; Gharb, Bahar Bassiri; Rampazzo, Antonio; Perrone, Francesco; Chen, Shih-Heng; Trignano, Emilio. - In: SURGERY. - ISSN 0039-6060. - 149:5(2011), pp. 662-671. [10.1016/j.surg.2010.11.020]

Simultaneous restoration of voice function and digestive tract continuity in patients with synchronous primaries of hypopharynx and thoracic esophagus with pedicled ileocolon flap

Trignano, Emilio
2011-01-01

Abstract

Background. Defects involving hypopharynx, cervical, and thoracic esophagus are challenging to reconstruct, and the available procedures usually leave patients voiceless. We describe our experience with a modified pedicled ileocolon flap for the reconstruction of alimentary conduit and voice in patients undergoing hypopharyngo-laryngectomy and total esophagectomy.Methods. Between January 1995 and December 2008, 7 patients underwent reconstruction of the digestive tract and voice function with a pedicled ileocolon flap because of extensive defects involving larynx, hyphopharynx, cervical, and thoracic esophagus. Patient's charts were reviewed and appropriate clinical data were evaluated.Results. All patients were male with a mean age of 58 years. The continuity of the digestive tract was restored with ileum-colon (n = 1) or colon (n = 6). The voice tube was reconstructed with appendix (n = 1) or with terminal ileum (n = 6). The middle colic artery (n = 1) and left ascending colic artery (n = 6) were used as a pedicle. Five flaps were supercharged using ileocolic vessels. All the flaps survived completely. No intraoperative or in-hospital mortalities occurred. The mean hospital stay was 40 days. The mean follow-up was 22.4 months. Two patients died of local recurrence (1 patient) and distant metastasis (I patient). One patient died of the complications of pre-existing disease. At the last follow-up, the median deglutition score was 5/7. The median speech score for intelligibility and fluency was 3, and 4 for loudness. The maximum phonation time was 7.57 s. The average sound pressure loudness and fundamental frequency were, respectively, 59 +/- 3 dB and 133 +/- 33 Hz.Conclusion. The pedicled ileocolon flap as used in this series proved to be a safe and reliable technique for simultaneous reconstruction of voice and digestive tract. (Surgery 2011;149:662-71.)
2011
Simultaneous restoration of voice function and digestive tract continuity in patients with synchronous primaries of hypopharynx and thoracic esophagus with pedicled ileocolon flap / Chen, Hung-Chi; Gharb, Bahar Bassiri; Rampazzo, Antonio; Perrone, Francesco; Chen, Shih-Heng; Trignano, Emilio. - In: SURGERY. - ISSN 0039-6060. - 149:5(2011), pp. 662-671. [10.1016/j.surg.2010.11.020]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/324699
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact