Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
Contrast-enhanced ultrasonography (CEUS) is increasingly being performed in Italy and Europe, particularly in the field of hepato-gastroenterology. Initially, it was mainly carried out to characterize focal hepatic lesions, but, since then, numerous studies have demonstrated its efficacy in the differential diagnosis of focal pancreatic pathologies (D’Onofrio et al. in Expert Rev Med Devices 7(2):257–273, 2010; Vidili et al. in J Ultrasound 22(1):41–51, 2019). The purpose of this paper is to provide Italian Medical Doctors with recommendations and thereby practical guidelines on the management of these patients. The present paper reports the final conclusions reached by the SIUMB guideline commission. This paper addresses particularly percutaneous ultrasound (US) examination (transabdominal US) and is drawn up specifically for publication.
SIUMB recommendations for focal pancreatic lesions / D'Onofrio, M.; de Sio, I.; Mirk, P.; Vidili, G.; Bertolotto, M.; Cantisani, V.; Schiavone, C.; Accogli, E.; Attili, F.; Basilico, R.; Brizi, M. G.; Buscarini, E.; Caiazzo, C.; Calliada, F.; Carriero, A.; Casadei, A.; Catalano, O.; D'Anneo, G.; De Prizio, M.; Di Candio, G.; Draghi, F.; Drudi, F. M.; Ferraioli, G.; Francica, G.; Granata, A.; Iannetti, G.; Maconi, G.; Magnolfi, F.; Mirk, P.; Piscaglia, F.; Pompili, M.; Rapaccini, G. L.; Sconfienza, L. M.; Serra, C.; Soresi, M.; Speca, S.; Stramare, R.; Tarantino, L.; Valentino, M.; Vallone, G.. - In: JOURNAL OF ULTRASOUND. - ISSN 1971-3495. - 23:4(2020), pp. 599-606. [10.1007/s40477-020-00522-2]
SIUMB recommendations for focal pancreatic lesions
D'Onofrio M.;de Sio I.;Mirk P.;Vidili G.;Bertolotto M.;Cantisani V.;Schiavone C.;Accogli E.;Attili F.;Basilico R.;Brizi M. G.;Buscarini E.;Caiazzo C.;Calliada F.;Carriero A.;Casadei A.;Catalano O.;D'Anneo G.;De Prizio M.;Di Candio G.;Draghi F.;Drudi F. M.;Ferraioli G.;Francica G.;Granata A.;Iannetti G.;Maconi G.;Magnolfi F.;Mirk P.;Piscaglia F.;Pompili M.;Rapaccini G. L.;Sconfienza L. M.;Serra C.;Soresi M.;Speca S.;Stramare R.;Tarantino L.;Valentino M.;Vallone G.
2020-01-01
Abstract
Contrast-enhanced ultrasonography (CEUS) is increasingly being performed in Italy and Europe, particularly in the field of hepato-gastroenterology. Initially, it was mainly carried out to characterize focal hepatic lesions, but, since then, numerous studies have demonstrated its efficacy in the differential diagnosis of focal pancreatic pathologies (D’Onofrio et al. in Expert Rev Med Devices 7(2):257–273, 2010; Vidili et al. in J Ultrasound 22(1):41–51, 2019). The purpose of this paper is to provide Italian Medical Doctors with recommendations and thereby practical guidelines on the management of these patients. The present paper reports the final conclusions reached by the SIUMB guideline commission. This paper addresses particularly percutaneous ultrasound (US) examination (transabdominal US) and is drawn up specifically for publication.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/285620
Citazioni
ND
6
5
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.