PURPOSE: To study the efficacy of a single 0.7 mg dexamethasone intravitreal implant in vitrectomized eyes with refractory macular edema secondary to combined cataract extraction and macular pucker removal. METHODS: In 8 eyes of 8 consecutive patients with refractory macular edema secondary to combined cataract extraction and 25-gauge vitrectomy with internal limiting membrane peeling for macular pucker removal, the injection of the 0.7 mg dexamethasone implant was performed. Best-corrected visual acuity, central retinal thickness measured by spectral domain optical coherence tomography, and intraocular pressure were evaluated at baseline, 1 month, and 6 months. RESULTS: After a mean follow-up of 6.75 ± 0.71 months, best-corrected visual acuity was significantly increased (P < 0.0001) from 20/50 to 20/23 (P < 0.0001), mean central retinal thickness decreased significantly from 439 ± 45 μm to 296 ± 49 μm (P < 0.0001), and intraocular pressure changed significantly (P = 0.02) from 14.63 ± 1.19 to 16 ± 0.93. In no case postoperative hypotony or other complication was observed. CONCLUSION: A single injection of the 0.7 mg dexamethasone intravitreal implant resulted effective in the treatment of refractory macular edema secondary to combined cataract extraction and vitrectomy for macular pucker removal allowing a stable visual acuity recovery.

Abstract PURPOSE:: To study the efficacy of a single 0.7 mg dexamethasone intravitreal implant in vitrectomized eyes with refractory macular edema secondary to combined cataract extraction and macular pucker removal. METHODS:: In 8 eyes of 8 consecutive patients with refractory macular edema secondary to combined cataract extraction and 25-gauge vitrectomy with internal limiting membrane peeling for macular pucker removal, the injection of the 0.7 mg dexamethasone implant was performed. Best-corrected visual acuity, central retinal thickness measured by spectral domain optical coherence tomography, and intraocular pressure were evaluated at baseline, 1 month, and 6 months. RESULTS:: After a mean follow-up of 6.75 ± 0.71 months, best-corrected visual acuity was significantly increased (P < 0.0001) from 20/50 to 20/23 (P < 0.0001), mean central retinal thickness decreased significantly from 439 ± 45 μm to 296 ± 49 μm (P < 0.0001), and intraocular pressure changed significantly (P = 0.02) from 14.63 ± 1.19 to 16 ± 0.93. In no case postoperative hypotony or other complication was observed. CONCLUSION:: A single injection of the 0.7 mg dexamethasone intravitreal implant resulted effective in the treatment of refractory macular edema secondary to combined cataract extraction and vitrectomy for macular pucker removal allowing a stable visual acuity recovery.

Intravitreal dexamethasone implant for refractory macular edema secondary to vitrectomy for macular pucker / Furino, C; Boscia, Francesco; Recchimurzo, F.; Sborgia, N; Alessio, C.. - In: RETINA. - ISSN 0275-004X. - 34:8(2014), pp. 1612-1616. [10.1097/IAE.0000000000000105]

Intravitreal dexamethasone implant for refractory macular edema secondary to vitrectomy for macular pucker

BOSCIA, Francesco;
2014-01-01

Abstract

Abstract PURPOSE:: To study the efficacy of a single 0.7 mg dexamethasone intravitreal implant in vitrectomized eyes with refractory macular edema secondary to combined cataract extraction and macular pucker removal. METHODS:: In 8 eyes of 8 consecutive patients with refractory macular edema secondary to combined cataract extraction and 25-gauge vitrectomy with internal limiting membrane peeling for macular pucker removal, the injection of the 0.7 mg dexamethasone implant was performed. Best-corrected visual acuity, central retinal thickness measured by spectral domain optical coherence tomography, and intraocular pressure were evaluated at baseline, 1 month, and 6 months. RESULTS:: After a mean follow-up of 6.75 ± 0.71 months, best-corrected visual acuity was significantly increased (P < 0.0001) from 20/50 to 20/23 (P < 0.0001), mean central retinal thickness decreased significantly from 439 ± 45 μm to 296 ± 49 μm (P < 0.0001), and intraocular pressure changed significantly (P = 0.02) from 14.63 ± 1.19 to 16 ± 0.93. In no case postoperative hypotony or other complication was observed. CONCLUSION:: A single injection of the 0.7 mg dexamethasone intravitreal implant resulted effective in the treatment of refractory macular edema secondary to combined cataract extraction and vitrectomy for macular pucker removal allowing a stable visual acuity recovery.
2014
PURPOSE: To study the efficacy of a single 0.7 mg dexamethasone intravitreal implant in vitrectomized eyes with refractory macular edema secondary to combined cataract extraction and macular pucker removal. METHODS: In 8 eyes of 8 consecutive patients with refractory macular edema secondary to combined cataract extraction and 25-gauge vitrectomy with internal limiting membrane peeling for macular pucker removal, the injection of the 0.7 mg dexamethasone implant was performed. Best-corrected visual acuity, central retinal thickness measured by spectral domain optical coherence tomography, and intraocular pressure were evaluated at baseline, 1 month, and 6 months. RESULTS: After a mean follow-up of 6.75 ± 0.71 months, best-corrected visual acuity was significantly increased (P < 0.0001) from 20/50 to 20/23 (P < 0.0001), mean central retinal thickness decreased significantly from 439 ± 45 μm to 296 ± 49 μm (P < 0.0001), and intraocular pressure changed significantly (P = 0.02) from 14.63 ± 1.19 to 16 ± 0.93. In no case postoperative hypotony or other complication was observed. CONCLUSION: A single injection of the 0.7 mg dexamethasone intravitreal implant resulted effective in the treatment of refractory macular edema secondary to combined cataract extraction and vitrectomy for macular pucker removal allowing a stable visual acuity recovery.
Intravitreal dexamethasone implant for refractory macular edema secondary to vitrectomy for macular pucker / Furino, C; Boscia, Francesco; Recchimurzo, F.; Sborgia, N; Alessio, C.. - In: RETINA. - ISSN 0275-004X. - 34:8(2014), pp. 1612-1616. [10.1097/IAE.0000000000000105]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/178102
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? ND
social impact