The mixed-signal PRIMA-chip has been developed for sensitive-position silicon detector in proton imaging application. The chip is based upon the binary readout architecture which, providing fully parallel signal processing, is a good solution for high intensity radiation application. It includes 32-front-end channels with a charge preamplifier, a shaper and a comparator. In order to adjust the comparator thresholds, each channel contains a 8-bit DAC, programmed using an I2C like interface. The PRIMA-chip has been fabricated using the AMS 0.35 μm standard CMOS process and its performances have been tested coupling it to the detectors used in the tracker assembled for the pCT (proton Computed Tomography) apparatus.

A binary readout chip for silicon microstrip detector in proton imaging application / Sipala, Valeria; Bruzzi, M.; Bondì, M.; Bonanno, D.; Cadeddu, S.; Carpinelli, Massimo; Cirrone, G. A. P.; Civinini, C.; Cuttone, G.; Lai, A.; Leonora, E.; Presti, D. Lo; Maccioni, G.; Pallotta, S.; Randazzo, N.; Scaringella, M.; Talamonti, C.; Tesi, M.; Vanzi, E.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 12:1(2017), pp. C01030-C01030. [10.1088/1748-0221/12/01/C01030]

A binary readout chip for silicon microstrip detector in proton imaging application

SIPALA, Valeria;CARPINELLI, Massimo;
2017-01-01

Abstract

The mixed-signal PRIMA-chip has been developed for sensitive-position silicon detector in proton imaging application. The chip is based upon the binary readout architecture which, providing fully parallel signal processing, is a good solution for high intensity radiation application. It includes 32-front-end channels with a charge preamplifier, a shaper and a comparator. In order to adjust the comparator thresholds, each channel contains a 8-bit DAC, programmed using an I2C like interface. The PRIMA-chip has been fabricated using the AMS 0.35 μm standard CMOS process and its performances have been tested coupling it to the detectors used in the tracker assembled for the pCT (proton Computed Tomography) apparatus.
2017
Inglese
12
1
C01030
C01030
http://iopscience.iop.org/article/10.1088/1748-0221/12/01/C01030/pdf
Esperti anonimi
Front-end electronics for detector readout; Instrumentation for hadron therapy; Particle tracking detectors; VLSI circuits; Instrumentation; Mathematical Physics
Internazionale
No
Sipala, Valeria; Bruzzi, M.; Bondì, M.; Bonanno, D.; Cadeddu, S.; Carpinelli, Massimo; Cirrone, G. A. P.; Civinini, C.; Cuttone, G.; Lai, A.; Leonora,...espandi
A binary readout chip for silicon microstrip detector in proton imaging application / Sipala, Valeria; Bruzzi, M.; Bondì, M.; Bonanno, D.; Cadeddu, S.; Carpinelli, Massimo; Cirrone, G. A. P.; Civinini, C.; Cuttone, G.; Lai, A.; Leonora, E.; Presti, D. Lo; Maccioni, G.; Pallotta, S.; Randazzo, N.; Scaringella, M.; Talamonti, C.; Tesi, M.; Vanzi, E.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 12:1(2017), pp. C01030-C01030. [10.1088/1748-0221/12/01/C01030]
info:eu-repo/semantics/article
1 Contributo su Rivista::1.1 Articolo in rivista
262
19
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/174237
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact