The reduced cross-section method (RCSM) is included in Eurocode 5 (EN-1995-1-2) for the design of timber members in fire conditions. The method considers the strength and stiffness reduction beneath the charred layer by adding an additional depth (known as the ‘zero-strength’ layer) to the charring depth. The zero strength layer is one of the key parameters for the fire design of timber members. Recently, some concerns have been raised that the zero-strength layer might be nonconservative in some applications. This paper presents the background to the RCSM, followed by a short discussion on the mechanical assumptions, simplifications and possible limitations of the method itself. Further, it discusses determination of the zero-strength layer thickness for members in bending, tension and compression, and provides guidelines on the use of standard experimental tests to determine this quantity. For demonstration of the determination procedure, the results of fire tests in bending, tension and compression were analysed following the described procedure. Results show that the zero-strength layer exceeds the value used in practice, indicate that the method of Eurocode 5 may be non-conservative and should be revised.

The reduced cross-section method for the evaluation of the fire resistance of timber members - Discussion and determination of the zero-strength layer / Fragiacomo, Massimo. - In: FIRE TECHNOLOGY. - ISSN 0015-2684. - 51:6(2015), pp. 1285-1309. [10.1007/s10694-014-0421-6]

The reduced cross-section method for the evaluation of the fire resistance of timber members - Discussion and determination of the zero-strength layer

FRAGIACOMO, Massimo
2015-01-01

Abstract

The reduced cross-section method (RCSM) is included in Eurocode 5 (EN-1995-1-2) for the design of timber members in fire conditions. The method considers the strength and stiffness reduction beneath the charred layer by adding an additional depth (known as the ‘zero-strength’ layer) to the charring depth. The zero strength layer is one of the key parameters for the fire design of timber members. Recently, some concerns have been raised that the zero-strength layer might be nonconservative in some applications. This paper presents the background to the RCSM, followed by a short discussion on the mechanical assumptions, simplifications and possible limitations of the method itself. Further, it discusses determination of the zero-strength layer thickness for members in bending, tension and compression, and provides guidelines on the use of standard experimental tests to determine this quantity. For demonstration of the determination procedure, the results of fire tests in bending, tension and compression were analysed following the described procedure. Results show that the zero-strength layer exceeds the value used in practice, indicate that the method of Eurocode 5 may be non-conservative and should be revised.
2015
The reduced cross-section method for the evaluation of the fire resistance of timber members - Discussion and determination of the zero-strength layer / Fragiacomo, Massimo. - In: FIRE TECHNOLOGY. - ISSN 0015-2684. - 51:6(2015), pp. 1285-1309. [10.1007/s10694-014-0421-6]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/139565
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact