This paper presents the results of long-term experimental tests performed on prefabricated timber–concrete composite beams intended for use in a proposed floor system, in which the concrete slab is prefabricated off-site and connected to the timber beam using one of two novel connection systems (either steel tubes inserted into the concrete slab and coach screws, or metal plates embedded in the concrete slab and nailed to the timber beams). In the experimental progra mme two beam specimens representing strips of composite floor were subjected to sustained (quasi-permanent service) loading for almost a year in an indoor, unheated and unconditioned environment. Throughout the test, mid-span deflection, relative slips at various connector locations, strains in the concrete slab and timber beam, and the ambient relative humidity and temperature, were continuously monitored. Both specimens showed only minor increases in deflection, slips and strains over time, demonstrating excellent overall long-term behaviour. The findings are consistent with a major advantage of prefabrication in this context; the concrete cures and can thus freely shrink before the slab is connected to the timber beam, thereby minimising stresses and deflection in the composite beam. Results of accompanying numerical analyses are also presented. A rigorous uniaxial finite element model was first validated against experimental results, and then used to predict the total deflection at the end of the 50-year service life of the specimens tested and of other specimens with different connection system not tested. The total deflection was found to be in the range of 3.5–4 times the elastic deflection due to the quasi-permanent load condition (excluding the self-weight of the beam). This value was always lower than the acceptable limit of span length over 200, with better predicted performance from stiffer connection systems such as notches cut in timber and glued-in dowels.

“Time-dependent behaviour of timber-concrete composite floors with prefabricated concrete slabs.” / Fragiacomo, Massimo; Lukaszewska, E.. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - 52:July 2013(2013), pp. 687-696. [10.1016/j.engstruct.2013.03.031]

“Time-dependent behaviour of timber-concrete composite floors with prefabricated concrete slabs.”

FRAGIACOMO, Massimo;
2013-01-01

Abstract

This paper presents the results of long-term experimental tests performed on prefabricated timber–concrete composite beams intended for use in a proposed floor system, in which the concrete slab is prefabricated off-site and connected to the timber beam using one of two novel connection systems (either steel tubes inserted into the concrete slab and coach screws, or metal plates embedded in the concrete slab and nailed to the timber beams). In the experimental progra mme two beam specimens representing strips of composite floor were subjected to sustained (quasi-permanent service) loading for almost a year in an indoor, unheated and unconditioned environment. Throughout the test, mid-span deflection, relative slips at various connector locations, strains in the concrete slab and timber beam, and the ambient relative humidity and temperature, were continuously monitored. Both specimens showed only minor increases in deflection, slips and strains over time, demonstrating excellent overall long-term behaviour. The findings are consistent with a major advantage of prefabrication in this context; the concrete cures and can thus freely shrink before the slab is connected to the timber beam, thereby minimising stresses and deflection in the composite beam. Results of accompanying numerical analyses are also presented. A rigorous uniaxial finite element model was first validated against experimental results, and then used to predict the total deflection at the end of the 50-year service life of the specimens tested and of other specimens with different connection system not tested. The total deflection was found to be in the range of 3.5–4 times the elastic deflection due to the quasi-permanent load condition (excluding the self-weight of the beam). This value was always lower than the acceptable limit of span length over 200, with better predicted performance from stiffer connection systems such as notches cut in timber and glued-in dowels.
2013
“Time-dependent behaviour of timber-concrete composite floors with prefabricated concrete slabs.” / Fragiacomo, Massimo; Lukaszewska, E.. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - 52:July 2013(2013), pp. 687-696. [10.1016/j.engstruct.2013.03.031]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/138087
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 66
  • ???jsp.display-item.citation.isi??? 53
social impact