A Phase-Contrast breast CT facility based on a high-resolution CdTe photon-counting detector is under development at Elettra, the Italian Synchrotron Radiation (SR) facility in Trieste. The CT system exploits propagation-based phasecontrast imaging and phase-retrieval algorithm. The voxel size is 57×57×50 μm3 and the delivered MGDs, about 5 mGy, are comparable with clinical breast CT systems. In the present contribution, the comparisons between histological breast cancers and full breast CT images are presented from samples of breast mastectomy. The high resolution of the breast CT images and low noise due to the phase contrast allow a very fine matching between X-ray CT and histology at acceptable delivered doses.

Lesion visibility in phase-contrast breast CT: Comparison with histological images / Longo, R.; Arfelli, F.; Donato, S.; Bonazza, D.; Brombal, L.; Contillo, A.; Cova, M. A.; Delogu, P.; Di Trapani, V.; Golosio, B.; Mettivier, G.; Oliva, P.; Rigon, L.; Taibi, A.; Tonutti, M.; Tromba, G.; Zanconati, F.. - 11513:(2020), p. 68. ( 15th International Workshop on Breast Imaging, IWBI 2020 bel 2020) [10.1117/12.2564202].

Lesion visibility in phase-contrast breast CT: Comparison with histological images

Oliva P.
Membro del Collaboration Group
;
2020-01-01

Abstract

A Phase-Contrast breast CT facility based on a high-resolution CdTe photon-counting detector is under development at Elettra, the Italian Synchrotron Radiation (SR) facility in Trieste. The CT system exploits propagation-based phasecontrast imaging and phase-retrieval algorithm. The voxel size is 57×57×50 μm3 and the delivered MGDs, about 5 mGy, are comparable with clinical breast CT systems. In the present contribution, the comparisons between histological breast cancers and full breast CT images are presented from samples of breast mastectomy. The high resolution of the breast CT images and low noise due to the phase contrast allow a very fine matching between X-ray CT and histology at acceptable delivered doses.
2020
Inglese
Van Ongeval, Chantal
Proceedings of SPIE - The International Society for Optical Engineering
15th International Workshop on Breast Imaging, IWBI 2020
11513
68
9781510638310
9781510638327
SPIE
2020
bel
Breast CT; Histology; Phase-contrast imaging; Synchrotron radiation
No
Lesion visibility in phase-contrast breast CT: Comparison with histological images / Longo, R.; Arfelli, F.; Donato, S.; Bonazza, D.; Brombal, L.; Contillo, A.; Cova, M. A.; Delogu, P.; Di Trapani, V.; Golosio, B.; Mettivier, G.; Oliva, P.; Rigon, L.; Taibi, A.; Tonutti, M.; Tromba, G.; Zanconati, F.. - 11513:(2020), p. 68. ( 15th International Workshop on Breast Imaging, IWBI 2020 bel 2020) [10.1117/12.2564202].
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
Longo, R.; Arfelli, F.; Donato, S.; Bonazza, D.; Brombal, L.; Contillo, A.; Cova, M. A.; Delogu, P.; Di Trapani, V.; Golosio, B.; Mettivier, G.; Oliva...espandi
273
17
none
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/240749
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact