Since 1998 we have developed X-Ray fluorescence tomography for microanalysis. All aspects were tackled starting with the reconstruction performed by FBP or ART methods. Self-absorption corrections were added and combined with Compton, transmission and fluorescence tomographies to obtain fully quantitative results. Automatic "smart scans" minimized overhead time scanning/aligning non-cylindrical objects. The scans were performed step-by-step or continuously with no overhead time. Focusing went from 5 to 1 micron range, using FZP or CRL lenses, and finally KB bent mirrors which yield sub-micron high intensity beams.Recently, we have performed the first quantitative 3D fluo-tomography by helical scanning. We are now studying energy dependent fluo-tomography for chemically-sensitive imaging of the internal structure of samples.This chronology yielded the present level of sophistication for both experiments and data treatment and finally a method ready for wide dissemination among scientists.

7 years of X-Ray fluorescence computed micro-tomography / Simionovici, A; Golosio, Bruno; Chukalina, M; Somogyi, A; Lemelle, L.. - 5535:(2004), pp. 232-242. (Intervento presentato al convegno Developments in X-Ray Tomography IV tenutosi a Denver, CO nel 4-6 August 2004) [10.1117/12.558948].

7 years of X-Ray fluorescence computed micro-tomography

GOLOSIO, Bruno;
2004-01-01

Abstract

Since 1998 we have developed X-Ray fluorescence tomography for microanalysis. All aspects were tackled starting with the reconstruction performed by FBP or ART methods. Self-absorption corrections were added and combined with Compton, transmission and fluorescence tomographies to obtain fully quantitative results. Automatic "smart scans" minimized overhead time scanning/aligning non-cylindrical objects. The scans were performed step-by-step or continuously with no overhead time. Focusing went from 5 to 1 micron range, using FZP or CRL lenses, and finally KB bent mirrors which yield sub-micron high intensity beams.Recently, we have performed the first quantitative 3D fluo-tomography by helical scanning. We are now studying energy dependent fluo-tomography for chemically-sensitive imaging of the internal structure of samples.This chronology yielded the present level of sophistication for both experiments and data treatment and finally a method ready for wide dissemination among scientists.
2004
7 years of X-Ray fluorescence computed micro-tomography / Simionovici, A; Golosio, Bruno; Chukalina, M; Somogyi, A; Lemelle, L.. - 5535:(2004), pp. 232-242. (Intervento presentato al convegno Developments in X-Ray Tomography IV tenutosi a Denver, CO nel 4-6 August 2004) [10.1117/12.558948].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/69738
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact