As part of a program to investigate the feasibility of proton computed tomography, the most likely path (MLP) of protons inside an absorber was measured in a beam experiment using a silicon strip detector set-up with high position and angular resolution. The locations of 200 MeV protons were measured at three different absorber depth of PMMA (3.75, 6.25 and 12.5 cm) and binned in terms of the displacement and exit angle measured behind the absorber. The observed position distributions were compared to theoretical predictions showing that the location of the protons can be predicted with an accuracy of better than 0.5 mm

Prototype tracking studies for proton CT / Feldt, F; Heimann, J; Blumenkrantz, N; Lucia, D; Sadrozinski, H. F. W.; Seiden, A; Sowerwine, W; Williams, D. C.; Bashkirov, V; Schulte, R; Bruzzi, M; Menichelli, D; Scaringella, M; Cirrone, G. A. P.; Cuttone, G; Randazzo, N; Sipala, Valeria; LO PRESTI, D.. - 1:(2005), pp. 59-63. ( Nuclear Science Symposium and Medical Imaging Conference, IEEE 2005 Fajardo 23-29 Oct. 2005) [10.1109/NSSMIC.2005.1596207].

Prototype tracking studies for proton CT

SIPALA, Valeria;
2005-01-01

Abstract

As part of a program to investigate the feasibility of proton computed tomography, the most likely path (MLP) of protons inside an absorber was measured in a beam experiment using a silicon strip detector set-up with high position and angular resolution. The locations of 200 MeV protons were measured at three different absorber depth of PMMA (3.75, 6.25 and 12.5 cm) and binned in terms of the displacement and exit angle measured behind the absorber. The observed position distributions were compared to theoretical predictions showing that the location of the protons can be predicted with an accuracy of better than 0.5 mm
2005
Inglese
Nuclear Science Symposium Conference Record, 2005 IEEE
Nuclear Science Symposium and Medical Imaging Conference, IEEE 2005
1
59
63
5
0-7803-9221-3
23-29 Oct. 2005
Fajardo
Prototype tracking studies for proton CT / Feldt, F; Heimann, J; Blumenkrantz, N; Lucia, D; Sadrozinski, H. F. W.; Seiden, A; Sowerwine, W; Williams, D. C.; Bashkirov, V; Schulte, R; Bruzzi, M; Menichelli, D; Scaringella, M; Cirrone, G. A. P.; Cuttone, G; Randazzo, N; Sipala, Valeria; LO PRESTI, D.. - 1:(2005), pp. 59-63. ( Nuclear Science Symposium and Medical Imaging Conference, IEEE 2005 Fajardo 23-29 Oct. 2005) [10.1109/NSSMIC.2005.1596207].
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
Feldt, F; Heimann, J; Blumenkrantz, N; Lucia, D; Sadrozinski, H. F. W.; Seiden, A; Sowerwine, W; Williams, D. C.; Bashkirov, V; Schulte, R; Bruzzi, M;...espandi
273
18
none
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/67926
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact