UNI ISO 5707:2001 specifies that vacuum drop in the receiver shall be within 2 kPa, also in presence of liner slips and unit fall-offs. The purpose of this study was to compare the performances of 6 vacuum servo– controlled regulators currently used in milking systems. Results showed that most of the regulation systems exceed the noise limit of 80 dB(A) with a peak of 86 dB(A). Regulator leakages were always within the limits defined in ISO standards, however there were differences of 70 – 80% among the different models. Considering the sensitivity of regulation, the regulator performances were adequate. All the regulators were able to limit the vacuum drop within 2 kPa, with different values ranging from 0,19 to 0,35 kPa. Performing a dry fall-off test, the response rate of some regulators was very fast (0,93 s), while for others was more than double (2,51 s).

La normativa vigente sui requisiti costruttivi e prestazionali degli impianti di mungitura (UNI ISO 5707:2001) prescrive che la caduta di vuoto nel vaso terminale non ecceda i 2 kPa, anche in caso di caduta dei prendicapezzoli. Con l’intento di approfondire questa problematica, si effettuava il presente studio che compara le prestazioni di sei regolatori del vuoto servoassistiti scelti fra quelli comunemente utilizzati negli impianti di mungitura. Lo studio evidenziava una notevole disparità di risposta dei regolatori comparati per molti dei parametri utilizzati per valutarne l’efficienza. Il livello sonoro prodotto dalla maggioranza dei sistemi di regolazione superava il valore di soglia di 80 dB(A), con punte di 86 dB(A). Le perdite di regolazione erano sempre entro i limiti definiti dalle norme, tuttavia fra alcuni modelli si registravano differenze del 70-80%. In merito alla sensibilità di regolazione, le prestazioni delle valvole risultavano pienamente soddisfacenti. Tutti i regolatori mostravano una buona capacità di contenere la caduta di vuoto, anche se le differenze fra i modelli in alcuni casi erano molto marcate (0,19 kPa rispetto a 0,34-0,35 kPa). Riguardo alla prontezza di risposta del regolatore al verificarsi di un disturbo al sistema di mungitura (caduta simulata di un prendicapezzoli), ad alcune valvole erano sufficienti in media 0,93 s, mentre ad altre occorreva un tempo più che doppio (2,51 s).

Prove comparative di sistemi di regolazione del vuoto negli impianti di mungitura / Pazzona, Antonio Luigi; Murgia, Lelia; Caria, Maria. - (2005), pp. 1-8. (Intervento presentato al convegno VIII Conv. Naz. AIIA "L’ingegneria agraria per lo sviluppo sostenibile dell’area mediterranea" tenutosi a Catania nel 27-30 giugno).

Prove comparative di sistemi di regolazione del vuoto negli impianti di mungitura

PAZZONA, Antonio Luigi;MURGIA, Lelia;CARIA, Maria
2005-01-01

Abstract

UNI ISO 5707:2001 specifies that vacuum drop in the receiver shall be within 2 kPa, also in presence of liner slips and unit fall-offs. The purpose of this study was to compare the performances of 6 vacuum servo– controlled regulators currently used in milking systems. Results showed that most of the regulation systems exceed the noise limit of 80 dB(A) with a peak of 86 dB(A). Regulator leakages were always within the limits defined in ISO standards, however there were differences of 70 – 80% among the different models. Considering the sensitivity of regulation, the regulator performances were adequate. All the regulators were able to limit the vacuum drop within 2 kPa, with different values ranging from 0,19 to 0,35 kPa. Performing a dry fall-off test, the response rate of some regulators was very fast (0,93 s), while for others was more than double (2,51 s).
2005
88-901860-0-3
La normativa vigente sui requisiti costruttivi e prestazionali degli impianti di mungitura (UNI ISO 5707:2001) prescrive che la caduta di vuoto nel vaso terminale non ecceda i 2 kPa, anche in caso di caduta dei prendicapezzoli. Con l’intento di approfondire questa problematica, si effettuava il presente studio che compara le prestazioni di sei regolatori del vuoto servoassistiti scelti fra quelli comunemente utilizzati negli impianti di mungitura. Lo studio evidenziava una notevole disparità di risposta dei regolatori comparati per molti dei parametri utilizzati per valutarne l’efficienza. Il livello sonoro prodotto dalla maggioranza dei sistemi di regolazione superava il valore di soglia di 80 dB(A), con punte di 86 dB(A). Le perdite di regolazione erano sempre entro i limiti definiti dalle norme, tuttavia fra alcuni modelli si registravano differenze del 70-80%. In merito alla sensibilità di regolazione, le prestazioni delle valvole risultavano pienamente soddisfacenti. Tutti i regolatori mostravano una buona capacità di contenere la caduta di vuoto, anche se le differenze fra i modelli in alcuni casi erano molto marcate (0,19 kPa rispetto a 0,34-0,35 kPa). Riguardo alla prontezza di risposta del regolatore al verificarsi di un disturbo al sistema di mungitura (caduta simulata di un prendicapezzoli), ad alcune valvole erano sufficienti in media 0,93 s, mentre ad altre occorreva un tempo più che doppio (2,51 s).
Prove comparative di sistemi di regolazione del vuoto negli impianti di mungitura / Pazzona, Antonio Luigi; Murgia, Lelia; Caria, Maria. - (2005), pp. 1-8. (Intervento presentato al convegno VIII Conv. Naz. AIIA "L’ingegneria agraria per lo sviluppo sostenibile dell’area mediterranea" tenutosi a Catania nel 27-30 giugno).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/65425
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact