In the present work we report a study of the light response of a CsI(Tl) crystal readout by a SiPM to low energy protons, accelerated by the Tandem Van der Graaf at the Laboratori Nazionali del Sud (LNS)-INFN, Catania, Italy. The light yield was measured for protons of different kinetic energies, from 2.5 MeV to 24 MeV. We also derived the light attenuation length. The results of this work indicate that a CsI coupled with a SiPM-based modern readout solution allows for the detection of low energy signals.

Performance of a SiPM-based readout of a large CsI(Tl) crystal irradiated with low energy protons / Bondi, M.; Battaglien, M.; Carpinelli, M.; Celentano, A.; De Napoli, M.; De Vita, R.; Leonora, E.; Marsicano, L.; Randazzo, N.; Sipala, V.. - 2017-:(2017), pp. 1-2. ( 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 fra 2016) [10.1109/NSSMIC.2016.8069804].

Performance of a SiPM-based readout of a large CsI(Tl) crystal irradiated with low energy protons

Carpinelli, M.;Sipala, V.
2017-01-01

Abstract

In the present work we report a study of the light response of a CsI(Tl) crystal readout by a SiPM to low energy protons, accelerated by the Tandem Van der Graaf at the Laboratori Nazionali del Sud (LNS)-INFN, Catania, Italy. The light yield was measured for protons of different kinetic energies, from 2.5 MeV to 24 MeV. We also derived the light attenuation length. The results of this work indicate that a CsI coupled with a SiPM-based modern readout solution allows for the detection of low energy signals.
2017
Inglese
Bondì, M.; Battaglieri, M.; Carpinelli, M.; Celentano, A.; De Napoli, M.; De Vita, R.; Leonora, E.; Marsicano, L.; Randazzo, N.; Sipala, V.
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
2017-
1
2
2
9781509016426
Institute of Electrical and Electronics Engineers Inc.
2016
fra
Internazionale
Radiology, Nuclear Medicine and Imaging; Instrumentation; Nuclear and High Energy Physics; Electronic, Optical and Magnetic Materials
No
Performance of a SiPM-based readout of a large CsI(Tl) crystal irradiated with low energy protons / Bondi, M.; Battaglien, M.; Carpinelli, M.; Celentano, A.; De Napoli, M.; De Vita, R.; Leonora, E.; Marsicano, L.; Randazzo, N.; Sipala, V.. - 2017-:(2017), pp. 1-2. ( 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 fra 2016) [10.1109/NSSMIC.2016.8069804].
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
Bondi, M.; Battaglien, M.; Carpinelli, M.; Celentano, A.; De Napoli, M.; De Vita, R.; Leonora, E.; Marsicano, L.; Randazzo, N.; Sipala, V.
273
10
none
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/211637
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact