The established stability of carbon-paste electrodes (CPEs) in brain extracellular fluid was exploited to develop a voltammetric technique to monitor the dopamine metabolite, homovanillic acid (HVA), at 10 s intervals. At the scan rates needed for this time resolution, 3,4-dihydroxyphenylacetic acid (DOPAC), electrogenerated as a result of HVA oxidation, was observed in the cyclic staircase voltammograms, and this interfered with the straightforward reliable quantification of HVA. However, correction of the HVA signal, recorded in mixtures, with currents from the DOPAC and ascorbate regions of the voltammogram allowed the reproducible construction of well behaved HVA calibration plots. These showed good linearity, LOD values, selectivity and stability during six days of continuous CPE exposure to a lipid medium, which served as an in-vitro model of CPE implantation in brain tissue for future applications.

Development of a voltammetric technique for monitoring brain dopamine metabolism: correction of interference caused by DOPAC electrogenerated during homovanillic acid detection / ISMAEL AL, Mulla; JOHN P., Lowry; Serra, Pier Andrea; ROBERT D., O'Neill. - In: ANALYST. - ISSN 0003-2654. - 134:(2009), pp. 893-898.

Development of a voltammetric technique for monitoring brain dopamine metabolism: correction of interference caused by DOPAC electrogenerated during homovanillic acid detection

SERRA, Pier Andrea;
2009-01-01

Abstract

The established stability of carbon-paste electrodes (CPEs) in brain extracellular fluid was exploited to develop a voltammetric technique to monitor the dopamine metabolite, homovanillic acid (HVA), at 10 s intervals. At the scan rates needed for this time resolution, 3,4-dihydroxyphenylacetic acid (DOPAC), electrogenerated as a result of HVA oxidation, was observed in the cyclic staircase voltammograms, and this interfered with the straightforward reliable quantification of HVA. However, correction of the HVA signal, recorded in mixtures, with currents from the DOPAC and ascorbate regions of the voltammogram allowed the reproducible construction of well behaved HVA calibration plots. These showed good linearity, LOD values, selectivity and stability during six days of continuous CPE exposure to a lipid medium, which served as an in-vitro model of CPE implantation in brain tissue for future applications.
2009
Development of a voltammetric technique for monitoring brain dopamine metabolism: correction of interference caused by DOPAC electrogenerated during homovanillic acid detection / ISMAEL AL, Mulla; JOHN P., Lowry; Serra, Pier Andrea; ROBERT D., O'Neill. - In: ANALYST. - ISSN 0003-2654. - 134:(2009), pp. 893-898.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/77936
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact