The determination of enzymatic activity in sheep milk is still today a practically unexplored field of research. This study proposes and fully validates two analytical procedures (i.e. by means of UV–vis spectrophotometry and RP-HPLC methods) for the determination of c-glutamyltransferase activity in sheep milk. Both methods are characterised by low detection and quantification limits, excellent linearity over a wide enzymatic activity interval, very good repeatability and reproducibility, and are bias-free. The RPHPLC method provides better sensitivity and automation capability levels than that of UV–vis, and its use is hence suggested for screening purposes. These methods have been preliminarily tested with a number of real samples of whole sheep milk, obtaining an average c-glutamyltransferase activity value of 2.93 ± 0.50 U ml1 and a range from 2.72 ± 0.10 U ml1 to 3.46 ± 0.11 U ml1.

Assessment and validation of methods for the determination of γ-glutamyltransferase activity in sheep milk / Piga, C; Urgeghe, Pietro Paolo; Piredda, G; Scintu, Mf; Sanna, Gavino. - In: FOOD CHEMISTRY. - ISSN 0308-8146. - 115:4(2009), pp. 1519-1523. [10.1016/j.foodchem.2009.01.041]

Assessment and validation of methods for the determination of γ-glutamyltransferase activity in sheep milk

URGEGHE, Pietro Paolo;SANNA, Gavino
2009-01-01

Abstract

The determination of enzymatic activity in sheep milk is still today a practically unexplored field of research. This study proposes and fully validates two analytical procedures (i.e. by means of UV–vis spectrophotometry and RP-HPLC methods) for the determination of c-glutamyltransferase activity in sheep milk. Both methods are characterised by low detection and quantification limits, excellent linearity over a wide enzymatic activity interval, very good repeatability and reproducibility, and are bias-free. The RPHPLC method provides better sensitivity and automation capability levels than that of UV–vis, and its use is hence suggested for screening purposes. These methods have been preliminarily tested with a number of real samples of whole sheep milk, obtaining an average c-glutamyltransferase activity value of 2.93 ± 0.50 U ml1 and a range from 2.72 ± 0.10 U ml1 to 3.46 ± 0.11 U ml1.
2009
Assessment and validation of methods for the determination of γ-glutamyltransferase activity in sheep milk / Piga, C; Urgeghe, Pietro Paolo; Piredda, G; Scintu, Mf; Sanna, Gavino. - In: FOOD CHEMISTRY. - ISSN 0308-8146. - 115:4(2009), pp. 1519-1523. [10.1016/j.foodchem.2009.01.041]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/50202
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact