A simple method for the simultaneous identification and quantification of four 2,5-methylenedioxy derivatives of 4-thioamphetamine (ALEPH series) in plasma samples was developed. The method consists of solid-phase extraction (SPE) using a Bond Elut C18 cartridge and capillary electrophoresis coupled with electrospray ionisation mass spectrometry (CE/ESI-MS). The SPE method used required only simple steps and provided a clean extract from which identification of each drug was feasible, even at low concentrations. The method was validated according to international guidelines. The calibration curves were linear over the concentration range of 50 to 1000 ng/mL for all drugs with correlation coefficients that exceeded 0.998. The lower limits of detection of the drugs were 23–43 ng/mL. The absolute recoveries for the drugs were 64–92% and 75–96% at concentrations of 100 and 500 ng/mL, respectively. The validation data (precision, accuracy, and recovery) show the reproducibility and selectivity of the method. This clean and simple method allows the routine detection of designer drugs such as thioamphetamines which may become a serious problem in the control of illegal drugs.

Simultaneous determination of new thioamphetamine designer drugs in plasma by capillary electrophoresis coupled with mass spectrometry / Boatto, Gianpiero; Nieddu, M; Pirisi, Maria Antonietta; Dessi, G.. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - 21:22(2007), pp. 3716-3720. [10.1002/rcm.3273]

Simultaneous determination of new thioamphetamine designer drugs in plasma by capillary electrophoresis coupled with mass spectrometry

BOATTO, Gianpiero;PIRISI, Maria Antonietta;
2007-01-01

Abstract

A simple method for the simultaneous identification and quantification of four 2,5-methylenedioxy derivatives of 4-thioamphetamine (ALEPH series) in plasma samples was developed. The method consists of solid-phase extraction (SPE) using a Bond Elut C18 cartridge and capillary electrophoresis coupled with electrospray ionisation mass spectrometry (CE/ESI-MS). The SPE method used required only simple steps and provided a clean extract from which identification of each drug was feasible, even at low concentrations. The method was validated according to international guidelines. The calibration curves were linear over the concentration range of 50 to 1000 ng/mL for all drugs with correlation coefficients that exceeded 0.998. The lower limits of detection of the drugs were 23–43 ng/mL. The absolute recoveries for the drugs were 64–92% and 75–96% at concentrations of 100 and 500 ng/mL, respectively. The validation data (precision, accuracy, and recovery) show the reproducibility and selectivity of the method. This clean and simple method allows the routine detection of designer drugs such as thioamphetamines which may become a serious problem in the control of illegal drugs.
2007
Simultaneous determination of new thioamphetamine designer drugs in plasma by capillary electrophoresis coupled with mass spectrometry / Boatto, Gianpiero; Nieddu, M; Pirisi, Maria Antonietta; Dessi, G.. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - 21:22(2007), pp. 3716-3720. [10.1002/rcm.3273]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/44697
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 15
social impact