Objectives: The objectives of this study were to test: (1) the repeatability of ultrasonographic examination of the optic nerve sheath diameter (ONSD) in the cat; (2) the association between the ONSD and age, sex and body weight in healthy cats; and (3) the difference in the ONSD between healthy cats and those suffering from presumed intracranial hypertension (ICH). Methods: This study had a prospective, blinded, observational cross-sectional study design. Two groups of animals were considered: healthy cats (group A) and cats with a diagnosis of presumed ICH (group B). The ONSD was evaluated, measured and compared between the two groups via an ultrasonographic transpalpebral approach. Repeatability of the procedure was evaluated through the intraclass correlation coefficient (ICC). Data were statistically compared using the Student’s t-test and linear regression analysis. Results: A strong inter- and intraobserver ICC indicating good repeatability was observed. The interobserver ICC was 0.965 (P '0.05) for the right eye and 0.956 (P '0.05) for the left eye. The intraobserver ICC was 0.988 (P '0.05) and 0.984 (P '0.05) for the right and left eyes, respectively. In healthy cats the mean ± SD ONSD was 1.23 ± 0.11 mm (range 1–1.47 mm) and 1.23 ± 0.10 (range 1–1.4 mm) for right and left eyes, respectively. The ONSD was not related to sex or weight; a weak relationship was observed with age. In group B, the mean ONSD was 1.68 ± 0.13 mm (range 1.5–1.9 mm) and 1.61 ± 0.15 mm (range 1.4–1.9 mm) for the right and left eyes, respectively. In group B, the ONSD was statistically significantly larger than in group A, the healthy cats (P '0.001). Conclusions and relevance: The transpalpebral ultrasonographic technique is a non-invasive, feasible and reproducible method to measure ONSD both in healthy cats and in cats suffering from suspected ICH.

Repeatability of ultrasound examination of the optic nerve sheath diameter in the adult cat: comparison between healthy cats and cats suffering from presumed intracranial hypertension / Evangelisti, M. A.; Carta, G.; Burrai, G. P.; Pinna Parpaglia, M. L.; Cubeddu, F.; Ballocco, I.; Puggioni, A.; Manunta, L.. - In: JOURNAL OF FELINE MEDICINE AND SURGERY. - ISSN 1098-612X. - 22:10(2020), pp. 959-965. [10.1177/1098612X19898006]

Repeatability of ultrasound examination of the optic nerve sheath diameter in the adult cat: comparison between healthy cats and cats suffering from presumed intracranial hypertension

Evangelisti M. A.;Carta G.;Burrai G. P.;Pinna Parpaglia M. L.;Cubeddu F.;Ballocco I.;Manunta L.
2020-01-01

Abstract

Objectives: The objectives of this study were to test: (1) the repeatability of ultrasonographic examination of the optic nerve sheath diameter (ONSD) in the cat; (2) the association between the ONSD and age, sex and body weight in healthy cats; and (3) the difference in the ONSD between healthy cats and those suffering from presumed intracranial hypertension (ICH). Methods: This study had a prospective, blinded, observational cross-sectional study design. Two groups of animals were considered: healthy cats (group A) and cats with a diagnosis of presumed ICH (group B). The ONSD was evaluated, measured and compared between the two groups via an ultrasonographic transpalpebral approach. Repeatability of the procedure was evaluated through the intraclass correlation coefficient (ICC). Data were statistically compared using the Student’s t-test and linear regression analysis. Results: A strong inter- and intraobserver ICC indicating good repeatability was observed. The interobserver ICC was 0.965 (P '0.05) for the right eye and 0.956 (P '0.05) for the left eye. The intraobserver ICC was 0.988 (P '0.05) and 0.984 (P '0.05) for the right and left eyes, respectively. In healthy cats the mean ± SD ONSD was 1.23 ± 0.11 mm (range 1–1.47 mm) and 1.23 ± 0.10 (range 1–1.4 mm) for right and left eyes, respectively. The ONSD was not related to sex or weight; a weak relationship was observed with age. In group B, the mean ONSD was 1.68 ± 0.13 mm (range 1.5–1.9 mm) and 1.61 ± 0.15 mm (range 1.4–1.9 mm) for the right and left eyes, respectively. In group B, the ONSD was statistically significantly larger than in group A, the healthy cats (P '0.001). Conclusions and relevance: The transpalpebral ultrasonographic technique is a non-invasive, feasible and reproducible method to measure ONSD both in healthy cats and in cats suffering from suspected ICH.
2020
Repeatability of ultrasound examination of the optic nerve sheath diameter in the adult cat: comparison between healthy cats and cats suffering from presumed intracranial hypertension / Evangelisti, M. A.; Carta, G.; Burrai, G. P.; Pinna Parpaglia, M. L.; Cubeddu, F.; Ballocco, I.; Puggioni, A.; Manunta, L.. - In: JOURNAL OF FELINE MEDICINE AND SURGERY. - ISSN 1098-612X. - 22:10(2020), pp. 959-965. [10.1177/1098612X19898006]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/240500
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact