The vestibulo-masseteric reflex (VMR or p11 wave), the acoustic-masseteric reflex (AMR or p1/n21 wave) and the mixed vestibulo-cochlear p11/n21 potential are responses of masseter muscles to sound that can be employed to evaluate brainstem function. This study was aimed at establishing the test–retest reliability and responsiveness of these reflex parameters according to the type of electrode configuration. Twenty-two healthy volunteers (M:F = 11:11; mean age 25.3 ± 5.2 years) participated in two testing sessions separated by one week. Zygomatic and mandibular montages were compared following unilateral and bilateral stimulations. For reliability purposes, intraclass correlation coefficient (ICC), coefficient of variation of the method error (CVME) and standard error of measurement (SEM) were calculated. The minimal detectable difference (MDD) was also determined as a measure of responsiveness. Both VMR (p11 wave) and AMR could be consistently evoked from test to retest, although the frequency rate was significantly higher (all p values ≤ 0.009) with zygomatic (VMR: 97.7–100%; AMR: 86.9–97.6%) than mandibular montage (VMR: 84.7–89.8%; AMR: 65.0–67.8%), with no significant differences between unilateral and bilateral stimulations. Good-to-excellent reliability and responsiveness (high ICC, low CVME, SEM and MDD scores) were detected for corrected amplitudes and peak latencies for all reflex responses, whereas raw amplitudes were associated to poor reliability. The reliability of the zygomatic montage proved superior to the mandibular montage for all reflex responses. Given their high test–retest consistency and capability to study different features of the reflex arch, both peak latencies and corrected amplitudes should be reported and considered in the interpretation of reflex testing results.

The vestibulo-masseteric reflex and the acoustic-masseteric reflex: a reliability and responsiveness study in healthy subjects / Loi, Nicola; Manca, Andrea; Ginatempo, Francesca; Deriu, Franca. - In: EXPERIMENTAL BRAIN RESEARCH. - ISSN 1432-1106. - (2020). [10.1007/s00221-020-05804-z]

The vestibulo-masseteric reflex and the acoustic-masseteric reflex: a reliability and responsiveness study in healthy subjects

Nicola Loi;Andrea Manca;Francesca Ginatempo;Franca Deriu
2020-01-01

Abstract

The vestibulo-masseteric reflex (VMR or p11 wave), the acoustic-masseteric reflex (AMR or p1/n21 wave) and the mixed vestibulo-cochlear p11/n21 potential are responses of masseter muscles to sound that can be employed to evaluate brainstem function. This study was aimed at establishing the test–retest reliability and responsiveness of these reflex parameters according to the type of electrode configuration. Twenty-two healthy volunteers (M:F = 11:11; mean age 25.3 ± 5.2 years) participated in two testing sessions separated by one week. Zygomatic and mandibular montages were compared following unilateral and bilateral stimulations. For reliability purposes, intraclass correlation coefficient (ICC), coefficient of variation of the method error (CVME) and standard error of measurement (SEM) were calculated. The minimal detectable difference (MDD) was also determined as a measure of responsiveness. Both VMR (p11 wave) and AMR could be consistently evoked from test to retest, although the frequency rate was significantly higher (all p values ≤ 0.009) with zygomatic (VMR: 97.7–100%; AMR: 86.9–97.6%) than mandibular montage (VMR: 84.7–89.8%; AMR: 65.0–67.8%), with no significant differences between unilateral and bilateral stimulations. Good-to-excellent reliability and responsiveness (high ICC, low CVME, SEM and MDD scores) were detected for corrected amplitudes and peak latencies for all reflex responses, whereas raw amplitudes were associated to poor reliability. The reliability of the zygomatic montage proved superior to the mandibular montage for all reflex responses. Given their high test–retest consistency and capability to study different features of the reflex arch, both peak latencies and corrected amplitudes should be reported and considered in the interpretation of reflex testing results.
2020
The vestibulo-masseteric reflex and the acoustic-masseteric reflex: a reliability and responsiveness study in healthy subjects / Loi, Nicola; Manca, Andrea; Ginatempo, Francesca; Deriu, Franca. - In: EXPERIMENTAL BRAIN RESEARCH. - ISSN 1432-1106. - (2020). [10.1007/s00221-020-05804-z]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/232391
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact