The Alpha Magnetic Spectrometer (AMS-02) is an astroparticle physics detector that has been installed on the International Space Station (ISS) in May 2011. The purpose of the experiment is to study with unprecedented precision and statistics cosmic-ray particles in an energy range from 0.5 GeV to few TeV. The AMS-02 Tracker system accurately determines the trajectory and absolute charge (Z) of cosmic rays by multiple measurements of the coordinates in nine layers of double-sided silicon micro-strip detectors. Given the high dynamic range of the front-end electronics, nuclei from hydrogen up to iron and above can be identified. The charge resolution could be naturally degraded by a number of detector effects that need to be carefully accounted for. In this contribution we describe the procedure that has been used to accurately calibrate the Tracker response. Finally we will discuss the Tracker calibration stability with time.

Nuclei charge measurement with the AMS-02 silicon tracker / Ambrosi, G.; Azzarello, P.; Battiston, R.; Bazo, J.; Bertucci, B.; Choumilov, E.; Choutko, V.; Crispoltoni, M.; Delgado, C.; Duranti, M.; Donnini, F.; D'Urso, Domenico; Fiandrini, E.; Formato, V.; Graziani, M.; Habiby, M.; Haino, S.; Ionica, M.; Kanishchev, K.; Nozzoli, F.; Oliva, A.; Paniccia, M.; Pizzolotto, C.; Pohl, M.; Qin, X.; Rapin, D.; Saouter, P.; Tomassetti, N.; Vitale, V.; Vitillo, S.; Wu, X.; Zhang, Z.; Zuccon, P.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - 30-:(2015). (Intervento presentato al convegno 34th International Cosmic Ray Conference, ICRC 2015 tenutosi a nld nel 2015).

Nuclei charge measurement with the AMS-02 silicon tracker

D'URSO, Domenico;
2015-01-01

Abstract

The Alpha Magnetic Spectrometer (AMS-02) is an astroparticle physics detector that has been installed on the International Space Station (ISS) in May 2011. The purpose of the experiment is to study with unprecedented precision and statistics cosmic-ray particles in an energy range from 0.5 GeV to few TeV. The AMS-02 Tracker system accurately determines the trajectory and absolute charge (Z) of cosmic rays by multiple measurements of the coordinates in nine layers of double-sided silicon micro-strip detectors. Given the high dynamic range of the front-end electronics, nuclei from hydrogen up to iron and above can be identified. The charge resolution could be naturally degraded by a number of detector effects that need to be carefully accounted for. In this contribution we describe the procedure that has been used to accurately calibrate the Tracker response. Finally we will discuss the Tracker calibration stability with time.
2015
Nuclei charge measurement with the AMS-02 silicon tracker / Ambrosi, G.; Azzarello, P.; Battiston, R.; Bazo, J.; Bertucci, B.; Choumilov, E.; Choutko, V.; Crispoltoni, M.; Delgado, C.; Duranti, M.; Donnini, F.; D'Urso, Domenico; Fiandrini, E.; Formato, V.; Graziani, M.; Habiby, M.; Haino, S.; Ionica, M.; Kanishchev, K.; Nozzoli, F.; Oliva, A.; Paniccia, M.; Pizzolotto, C.; Pohl, M.; Qin, X.; Rapin, D.; Saouter, P.; Tomassetti, N.; Vitale, V.; Vitillo, S.; Wu, X.; Zhang, Z.; Zuccon, P.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - 30-:(2015). (Intervento presentato al convegno 34th International Cosmic Ray Conference, ICRC 2015 tenutosi a nld nel 2015).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11388/179720
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact